behrotest® Workstations for the Aqua Regia Digestion of Heavy Metal Samples
|
 |
Workstation Model SMA-ARB
The behrotest® workstation model SMA-ARB is a basic system for simultaneous aqua regia digestion of either 6 or 12 samples for heavy metals analysis.
System Components:
- Precision 6 or 12 sample SMA heating block for round-bottom sample vessels of 41.8 mm dia. Temperature range: 20 - 299°C.
- External mod. ET 2 time/temperature controller (operating range 20
- 450 °C). Time settings: 1 - 999 min. and continuous operation.
- 6 or 12 SR 2 250 ml round-bottom sample vessels with std. taper mouth and PVDF collar
- 6 or 12 SFK 50 Allihn reflux condensers
- 6 or 12 AS 1 absorbtion vessels
- SG/B stainless steel vessel holding frame for 6 or 12 sample vessels
- Support scaffold with cooling water distributor and storage holder for 6 or 12 condensers
Ordering Information:
| Description | Model | Stock No. |
| Basic configuration workstation for simultaneous aqua regia digestion of up to 6 samples for heavy metals analysis | SMA-ARB 6 | 804880009 |
| Basic configuration workstation for simultaneous aqua regia digestion of up to 12 samples for heavy metals analysis | SMA-ARB 12 | 804880010 |
Workstation Model SMA-ARM
The behrotest® SMA-ARM workstations are provided with a programmable microprocessor-controlled time/temp. controller as well as a fume manifold for drawing off the acid vapors. This results in greater convenience and functionality in routine laboratory operations.
System Components:
- Precision 6 or 12 sample SMA heating block for round-bottom sample vessels of 41.8 mm dia. Temperature range: 20 - 299°C
- External mod. TRS 200 time/temperature controller (operating range 20 - 399°C). Time settings: 1 -999 min. Continuous display of actual and desired temperatures, interval duration and remaining time. Up to 10 intervals programmable.
- 6 or 12 SR 2 250 ml round-bottom sample vessels with std. taper mouth and PVDF collar
- 6 or 12 SFK 50 Allihn reflux condensers
- 6 or 12 AS 1 absorbtion vessels
- PTFE sleeves for std. taper glass joints
- SG/B stainless steel vessel holding frame for 6 or 12 sample vessels
- TS bench-top stand and transport carrier for vessel holding frame
- Support scaffold with cooling water distributor and storage holder for 6 or 12 condensers
- Mod. AH fume manifold for drawing off the acid vapors in both 6 and 12 sample versions. Connects to scrubber suction unit (i.e. behrosog)
Ordering Information:
| Description | Model | Stock No. |
| Workstation for simultaneous aqua regia digestion of up to 6 samples for heavy metals analysis, incl. microprocessor time/temp. controller | SMA-ARM 6 | 804880011 |
| Workstation for simultaneous aqua regia digestion of up to 12 samples for heavy metals analysis, incl. microprocessor time/temp. controller | SMA-ARM 12 | 804880012 |
Workstation model SMA-ARE
The behrotest® SMA-ARE workstations are ideal for digestion of "difficult" samples, e.g. those which foam on heating. The programmable time/temp controller allows a sequence of up to 10 time intervals at selectable temperatures to be executed. Moreover, the SMA-ARE workstations include the behrosog acid vapor scrubber and the UK 12/1000 circulating/cooling unit for reflux condenser water.
System Components:
- Precision 6 or 12 sample SMA heating block for round-bottom sample vessels of 41.8 mm dia. Temperature range: 20 - 299°C.
- External mod. TRS 200 time/temperature controller (operating range 20 - 399°C). Time settings: 1 -999 min. Continuous display of actual and desired temperatures, interval duration and remaining time. Up to 10 intervals programmable.
- 6 or 12 SR 2 250 ml round-bottom sample vessels with std. taper mouth and PVDF collar
- 6 or 12 SFK 50 Allihn reflux condensers
- 6 or 12 AS 1 absorbtion vessels
- PTFE sleeves for std. taper glass joints
- SG/B stainless steel vessel holding frame for 6 or 12 sample vessels
- TS bench-top stand and transport carrier for vessel holding frame
- Support scaffold with cooling water distributor and storage holder for 6 or 12 condensers
- Mod. AH fume manifold for drawing off the acid vapors in both 6 and 12 sample versions. Connects to scrubber suction unit
- Behrosog suction unit with condensate trap and scrubber for acid vapors. Retains over 90% of the environmental contamination.
- Recirculating water cooler for reflux condensers makes wasteful and expensive use of tapwater for cooling in heavy metal digestion unnecessary.
Ordering Information:
| Description | Model | Stock No. | | High end workstation for simultaneous aqua regia digestion of up to 6 samples for heavy metals analysis, incl. programmable microprocessor-based time/temp. controller, acid vapor scrubber and recirculating water cooler for reflux condensers. | SMA-ARE 6 | 804880013 |
| High end workstation for simultaneous aqua regia digestion of up to 12 samples for heavy metals analysis, incl. programmable microprocessor-based time/temp. controller, acid vapor scrubber and recirculating water cooler for reflux condensers | SMA-ARE 12 | 804880014 |
Glassware expansion kit for 30 ml Soxhlet extraction in the SMA heating block systems |
| Glassware expansion kit for six 30 ml Soxhlet extractions, incl. vessels, extractors and Dimroth reflux condensers | | 804880015 |
| Glassware expansion kit for twelve 30 ml Soxhlet extractions, incl. vessels, extractors and Dimroth reflux condensers | | 804880016 |
|